DocumentCode :
1335851
Title :
Design and Testing of an Advanced Implantable Neuroprosthesis With Myoelectric Control
Author :
Hart, Ronald L. ; Bhadra, Niloy ; Montague, Fred W. ; Kilgore, Kevin L. ; Peckham, P. Hunter
Author_Institution :
Louis Stokes Veterans Affairs Med. Center, Cleveland FES Center, Cleveland, OH, USA
Volume :
19
Issue :
1
fYear :
2011
Firstpage :
45
Lastpage :
53
Abstract :
An implantable stimulator-telemeter (IST-12) was developed for applications in neuroprosthetic restoration of limb function in paralyzed individuals. The IST-12 provides 12 stimulation channels and two myoelectric signal (MES) channels. The MES circuitry includes a two-channel multiplexer, preamplifier, variable gain amplifier/bandpass filter, full-wave rectifier, and bin integrator. Power and control signals are transmitted from an external control unit to the IST-12 through an inductive link. Recorded MES signals are telemetered back to the external control unit through the same inductive link. Following bench testing, one device was implanted chronically in a dog for 15 months and evaluated. Conditions were identified in which MES could be recorded with minimal stimulus artifact. The ability to record MES in the presence of stimulation was verified, confirming the potential of the IST-12 to be used as a myoelectric controlled neuroprosthesis.
Keywords :
biomedical telemetry; electromyography; medical control systems; medical signal processing; neuromuscular stimulation; patient rehabilitation; prosthetics; IST-12; MES circuitry; advanced implantable neuroprosthesis; bandpass filter; bin integrator; control signals; external control unit; full-wave rectifier; implantable stimulator-telemeter; inductive link; limb function; myoelectric control; myoelectric controlled neuroprosthesis; myoelectric signal channels; neuroprosthetic restoration; power signals; preamplifier; recorded MES signals; two-channel multiplexer; variable gain amplifier; Electrodes; Implants; Lead; Muscles; Testing; Titanium; Wire; Biomedical recording; biomedical signal detection; biomedical telemetry; electromyography; implantable biomedical devices; neuromuscular stimulation; neuroprosthesis; Animals; Biofeedback, Psychology; Dogs; Electric Stimulation Therapy; Electromyography; Equipment Design; Equipment Failure Analysis; Humans; Movement Disorders; Prostheses and Implants; Telemetry; Therapy, Computer-Assisted;
fLanguage :
English
Journal_Title :
Neural Systems and Rehabilitation Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
1534-4320
Type :
jour
DOI :
10.1109/TNSRE.2010.2079952
Filename :
5585827