DocumentCode
1336939
Title
Calibration algorithm of the n-port vector network analyser using the general node equation
Author
Zhao, Wanfang ; Zhao, Y.-J. ; Qin, H.-B. ; Qiang, Lei ; Liu, B.
Author_Institution
Nanjing Univ. of Aeronaut. & Astronaut., Nanjing, China
Volume
4
Issue
6
fYear
2010
fDate
11/1/2010 12:00:00 AM
Firstpage
298
Lastpage
302
Abstract
A new and simple calibration algorithm using general node equations is proposed in the calibration of the n-port vector network analyser (VNA). The crosstalk error term is considered in the error model to achieve high precision. With the general node equations deduced from the general flow graph, the S-parameters can be finally derived. The actual S-parameters of a four-port device can be corrected and compared with measurement results by Agilent VNA E5071B. The good agreement attests the precision of the calibration algorithm.
Keywords
S-parameters; calibration; network analysers; S-parameter; calibration algorithm; crosstalk error; error model; node equation; vector network analyser;