Title :
Electromagnetic transducers close to high-temperature plasma in the thermonuclear fusion experiment RFX
Author :
Fiorentin, Pietro ; Peruzzo, Simone ; Pomaro, Nicola
Author_Institution :
Dept. of Electr. Eng., Padova Univ., Italy
fDate :
4/1/2000 12:00:00 AM
Abstract :
RFX is a magnetically confined fusion experiment in operation since 1992 in Padova, Italy. Analysis of the magnetic field is essential for the safe operation of the machine and the understanding of high-temperature plasma dynamics. Both of these issues require an accurate electromagnetic diagnostic system. In this paper, after a discussion of the problems related to magnetic measurements in fusion experiments, with particular reference to the RFX environment, the probes installed inside the vacuum vessel are described
Keywords :
electric current measurement; electromagnetic devices; fusion reactor instrumentation; plasma probes; plasma toroidal confinement; transducers; electric current measurement; electromagnetic diagnostics; electromagnetic transducers; high-temperature plasma; high-temperature plasma dynamics; magnetic confinement; magnetically confined fusion experiment; plasma measurement; probes; thermonuclear fusion experiment RFX; vacuum vessel; Fusion reactors; Magnetic confinement; Magnetic field measurement; Magnetic flux; Plasma confinement; Plasma measurements; Plasma temperature; Probes; Toroidal magnetic fields; Transducers;
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on