DocumentCode
1337985
Title
Wide area voltage protection
Author
Corsi, Sandro
Author_Institution
CESI S.p.A., Milan, Italy
Volume
4
Issue
10
fYear
2010
fDate
10/1/2010 12:00:00 AM
Firstpage
1164
Lastpage
1179
Abstract
Two very promising wide-area voltage protection (V-WAP) solutions, able to face stability and security problems in the transmission grid, are presented. Both require real-time effective risk indicators whose timely computing is a crucial issue. The first method makes use of a voltage instability index based on real-time computing of the Thevenin equivalent circuit seen by a given high voltage (HV) bus. The innovating algorithm utilised for the real-time adaptive identification of the Thevenin voltage and impedance equivalent values requires local phasor measurements at fast sampling rate. The unique ability of the second method is mainly because of an effective coordination with a supposed operating wide-area voltage regulation (V-WAR) modern system where the secondary and tertiary voltage regulations (SVR and TVR, respectively) operate according to their hierarchies. Evidence for the feasibility and simplicity in defining and developing an effective V-WAP solution once reliable real-time risk indicators are available is provided. The feasibility of the first method comes from the high computing speed of the local risk indicator at each area bus where a phasor measurement unit (PMU) is installed. The main simplification of the second method comes from the already existing and appropriate subdivision of the network into areas provided by the operating SVR, the same areas as those of the protection scheme intervention. From this starting point, a voltage stability index is proposed operating the area load shedding (LS) according to a simple and incontrovertible logic based on the real-time area control effort. Dynamic simulation results on the North Italy power system show the proposed protection scheme´s effectiveness and ability to achieve the continuity and stability of the controlled power system in front of a ramping load increase, by also containing the LS amount.
Keywords
equivalent circuits; load shedding; phase measurement; power system measurement; power system protection; power system security; power system stability; EHV stability; North Italy power system; PMU; Thevenin equivalent circuit; innovating algorithm; load shedding; local phasor measurements; real-time effective risk indicators; system security problems; voltage instability; voltage stability index; wide area voltage protection; wide-area voltage regulation;
fLanguage
English
Journal_Title
Generation, Transmission & Distribution, IET
Publisher
iet
ISSN
1751-8687
Type
jour
DOI
10.1049/iet-gtd.2009.0496
Filename
5587758
Link To Document