• DocumentCode
    1338255
  • Title

    Aging diagnosis of insulation systems by PD measurements. Extraction of partial discharge features in electrical treeing

  • Author

    Bozzo, R. ; Gemme, C. ; Guastavino, F. ; Cacciari, M. ; Contin, A. ; Montanari, G.C.

  • Author_Institution
    Genoa Univ., Italy
  • Volume
    5
  • Issue
    1
  • fYear
    1998
  • fDate
    2/1/1998 12:00:00 AM
  • Firstpage
    118
  • Lastpage
    124
  • Abstract
    The charge height values associated with PD measured during electrical tree inception and growth are processed according to the Weibull distribution. Test arrangements, based on the needle-plane electrode system, consider specimens having either a cavity at the tip or an intimate contact with insulation. It is shown that the Weibull-function parameters have close relation to discharges occurring in cavity and tree channels, and that an indication of inception of electrical trees can be obtained
  • Keywords
    Weibull distribution; ageing; insulation testing; partial discharges; trees (electrical); Weibull distribution; aging diagnosis; cavity; charge height; electrical treeing; insulation system; needle-plane electrode; partial discharge measurement; Aging; Charge measurement; Current measurement; Electric variables measurement; Electrodes; Insulation testing; Partial discharges; System testing; Trees - insulation; Weibull distribution;
  • fLanguage
    English
  • Journal_Title
    Dielectrics and Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1070-9878
  • Type

    jour

  • DOI
    10.1109/94.660788
  • Filename
    660788