DocumentCode
1338255
Title
Aging diagnosis of insulation systems by PD measurements. Extraction of partial discharge features in electrical treeing
Author
Bozzo, R. ; Gemme, C. ; Guastavino, F. ; Cacciari, M. ; Contin, A. ; Montanari, G.C.
Author_Institution
Genoa Univ., Italy
Volume
5
Issue
1
fYear
1998
fDate
2/1/1998 12:00:00 AM
Firstpage
118
Lastpage
124
Abstract
The charge height values associated with PD measured during electrical tree inception and growth are processed according to the Weibull distribution. Test arrangements, based on the needle-plane electrode system, consider specimens having either a cavity at the tip or an intimate contact with insulation. It is shown that the Weibull-function parameters have close relation to discharges occurring in cavity and tree channels, and that an indication of inception of electrical trees can be obtained
Keywords
Weibull distribution; ageing; insulation testing; partial discharges; trees (electrical); Weibull distribution; aging diagnosis; cavity; charge height; electrical treeing; insulation system; needle-plane electrode; partial discharge measurement; Aging; Charge measurement; Current measurement; Electric variables measurement; Electrodes; Insulation testing; Partial discharges; System testing; Trees - insulation; Weibull distribution;
fLanguage
English
Journal_Title
Dielectrics and Electrical Insulation, IEEE Transactions on
Publisher
ieee
ISSN
1070-9878
Type
jour
DOI
10.1109/94.660788
Filename
660788
Link To Document