Assessment of Vibrotactile Feedback on Postural Stability During Pseudorandom Multidirectional Platform Motion
Author :
Sienko, Kathleen H. ; Vichare, Vivek V. ; Balkwill, M. David ; Wall, Conrad, III
Author_Institution :
Dept. of Mech. Eng., Univ. of Michigan, Ann Arbor, MI, USA
Volume :
57
Issue :
4
fYear :
2010
fDate :
4/1/2010 12:00:00 AM
Firstpage :
944
Lastpage :
952
Abstract :
This study uses frequency-domain techniques and stabilogram diffusion analysis (SDA) to investigate the effect of vibrotactile feedback during continuous multidirectional perturbations of a support platform. Eight subjects with vestibular deficits were subjected to two-axis pseudorandom surface platform motion while donning a multiaxis vibrotactile feedback device that mapped body tilt estimates onto their torsos via a 3-row by 16-column array of tactile vibrators (tactors). Four tactor display configurations with spatial resolutions ranging between 22.5?? and 90??, in addition to the tactors off configuration, were evaluated. Power spectral density functions of body sway in the anterior-posterior (A/P) and medial-lateral (M/L) directions, and transfer functions between platform motion and body sway, were computed at frequencies ranging from 0.0178 to 3.56 Hz. Cross-spectral analysis revealed that the A/P responses were not significantly driven by M/L inputs, and vice versa, thus supporting the notion of independent A/P and M/L postural control. Vibrotactile feedback significantly decreased A/P and M/L spectral power, decreased transfer function gains up to a frequency of 1.8 and 0.6 Hz in the A/P and M/L directions, respectively, and increased phase leads above 0.3 Hz. SDA showed significantly decreased transition time for both A/P and M/L tilts, and decreased transition displacement and short-term diffusion coefficients for A/P tilt. However, the spatial resolution of the tactor displays did not affect subjects´ performance, thereby supporting the use of a lower spatial resolution display in future device designs.
Keywords :
biomechanics; biomedical measurement; frequency-domain analysis; neurophysiology; perturbation techniques; tactile sensors; touch (physiological); vibration measurement; anterior-posterior direction; body sway; continuous multidirectional perturbations; cross-spectral analysis; frequency 0.0178 Hz to 3.56 Hz; frequency-domain techniques; medial-lateral direction; postural stability; power spectral density functions; pseudorandom multidirectional platform motion; short-term diffusion coefficients; spatial resolution display; stabilogram diffusion analysis; tactile vibrators; tactor display configurations; torsos; transfer functions; transition displacement; two-axis pseudorandom surface platform motion; vestibular deficits; vibrotactile feedback; Balance; balance aid; frequency-domain analysis; postural control; stabilogram diffusion analysis (SDA); vibrotactile display; Biomedical Engineering; Data Interpretation, Statistical; Feedback, Sensory; Humans; Least-Squares Analysis; Monitoring, Ambulatory; Postural Balance; Signal Processing, Computer-Assisted; Touch; Vestibular Diseases; Vibration; Walking;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/TBME.2009.2036833
Filename :
5339195
Link To Document :
بازگشت