DocumentCode :
133882
Title :
Real time leak detection and isolation in pipelines: A comparison between Sliding Mode Observer and algebraic steady state method
Author :
Espinoza-Moreno, G. ; Begovich, O. ; Sanchez-Torres, J.
Author_Institution :
Center for Res. & Adv. Studies, Nat. Polytech. Inst., Zapopan, Mexico
fYear :
2014
fDate :
3-7 Aug. 2014
Firstpage :
748
Lastpage :
753
Abstract :
The purpose of this paper is to compare two different algorithms used to detect and isolate water leaks in a pipeline. One method is based on a Sliding Mode Observer and the second method is an Algebraic method obtained from the pipeline model in steady state. Because of the simplicity of both methods, they can be easily implemented. The methods were tested offline with real time data and the Algebraic method was also implemented online. Satisfactory results are shown through some experiments.
Keywords :
algebra; leak detection; mechanical engineering computing; observers; pipelines; variable structure systems; algebraic steady state method; pipeline model; real time data; real time water pipeline leak detection and isolation; sliding mode observer; Analytical models; Computational modeling; Fluids; Leak detection; Observers; Pipelines; Real-time systems;
fLanguage :
English
Publisher :
ieee
Conference_Titel :
World Automation Congress (WAC), 2014
Conference_Location :
Waikoloa, HI
Type :
conf
DOI :
10.1109/WAC.2014.6936130
Filename :
6936130
Link To Document :