DocumentCode :
1338909
Title :
AC Losses in \\hbox {Bi}_{2}\\hbox {Sr}_{2}\\hbox {Ca}_{2} \\hbox {Cu}_{3}\\hbox {O}_{10 + x} Tapes and a 3.15-m-Long Single-Phase Cable
Author :
Juul, Jeppe Søgaard ; Mølgaard, Esben Tore ; Jensen, Jens ; Andersen, Niels Hessel ; Abrahamsen, Asger Bech ; Willén, Dag ; Traholt, Chresten ; Thidemann, Carsten ; Lentge, Heidi
Author_Institution :
Niels Bohr Inst., Univ. of Copenhagen, Copenhagen, Denmark
Volume :
21
Issue :
6
fYear :
2011
Firstpage :
3599
Lastpage :
3603
Abstract :
The alternating-current losses in superconducting multifilament BiSCCO-2223 tapes and a 3.15-m single-phase test cable were measured at 77 K using an electrical transport method. The cable had an inner diameter of 42 mm; it was composed of a single layer of 31 multifilament tapes and had a critical current of Ic = 4.1 kA. The measured losses of the tapes were found to be in good agreement with the Norris ellipse (NE) model. The losses of the cable were, for high currents, found to be bounded by the monoblock and independent NE models.
Keywords :
bismuth compounds; calcium compounds; eddy current losses; high-temperature superconductors; magnetic leakage; multifilamentary superconductors; strontium compounds; superconducting cables; superconducting tapes; Bi2Sr2Ca2Cu3O10+x; Norris ellipse model; alternating-current losses; critical current; electrical transport method; inner diameter; monoblock model; single layer; single-phase test cable; size 3.15 m; size 42 mm; superconducting multifilament BiSCCO-2223 tapes; temperature 77 K; Critical current; Current measurement; High temperature superconductors; Integrated circuits; Loss measurement; Superconducting cables; High-temperature superconductors (HTSs); loss measurement; magnetic losses; multifilamentary superconductors;
fLanguage :
English
Journal_Title :
Applied Superconductivity, IEEE Transactions on
Publisher :
ieee
ISSN :
1051-8223
Type :
jour
DOI :
10.1109/TASC.2011.2166153
Filename :
6033053
Link To Document :