Performance study in energy efficiency on variable speed drive, VSD design for serting high lift pumping station
Author
Baharom, Mohd Faizal ; Jali, M.H. ; Nasir, M.N.M. ; Bohari, Z.H. ; Tarusan, S.A. ; Misran, M.H.
Author_Institution
Dept. of Electr. Eng., Univ. Tech. Malaysia Melaka, Durian Tunggal, Malaysia
fYear
2014
fDate
27-29 May 2014
Firstpage
328
Lastpage
331
Abstract
This paper describes the performances of variable speed Drive, VSD to enhance energy consumption in Water Treatment Plant. This study is focus on the comparisons between variable Speed Drive, VSD and RVSS to assess the pumping performance as well as energy efficiency in the WTP system. Based on the Layne Bowler pump characteristic, it clearly proved that the VSD is more reliable in term of speed and energy usage compared to RVSS. As results, by using VSD it will bring a lot of benefits for long term application and gives a lot of saving in ROI.
Keywords
variable speed drives; water treatment; Layne Bowler pump characteristic; RVSS; VSD design; energy efficiency; high lift pumping station; variable speed drive; water treatment plant; Actuators; Educational institutions; Energy consumption; Energy efficiency; Optimization; Power demand; Variable speed drives; Energy Efficiency; Layne Bowler; Variable Speed Drive (VSD); Water treatment Plant(WTP);