• DocumentCode
    134137
  • Title

    Performance study in energy efficiency on variable speed drive, VSD design for serting high lift pumping station

  • Author

    Baharom, Mohd Faizal ; Jali, M.H. ; Nasir, M.N.M. ; Bohari, Z.H. ; Tarusan, S.A. ; Misran, M.H.

  • Author_Institution
    Dept. of Electr. Eng., Univ. Tech. Malaysia Melaka, Durian Tunggal, Malaysia
  • fYear
    2014
  • fDate
    27-29 May 2014
  • Firstpage
    328
  • Lastpage
    331
  • Abstract
    This paper describes the performances of variable speed Drive, VSD to enhance energy consumption in Water Treatment Plant. This study is focus on the comparisons between variable Speed Drive, VSD and RVSS to assess the pumping performance as well as energy efficiency in the WTP system. Based on the Layne Bowler pump characteristic, it clearly proved that the VSD is more reliable in term of speed and energy usage compared to RVSS. As results, by using VSD it will bring a lot of benefits for long term application and gives a lot of saving in ROI.
  • Keywords
    variable speed drives; water treatment; Layne Bowler pump characteristic; RVSS; VSD design; energy efficiency; high lift pumping station; variable speed drive; water treatment plant; Actuators; Educational institutions; Energy consumption; Energy efficiency; Optimization; Power demand; Variable speed drives; Energy Efficiency; Layne Bowler; Variable Speed Drive (VSD); Water treatment Plant(WTP);
  • fLanguage
    English
  • Publisher
    ieee
  • Conference_Titel
    Technology Management and Emerging Technologies (ISTMET), 2014 International Symposium on
  • Conference_Location
    Bandung
  • Print_ISBN
    978-1-4799-3703-5
  • Type

    conf

  • DOI
    10.1109/ISTMET.2014.6936528
  • Filename
    6936528