Analysis of voltage tolerance of AC adjustable-speed drives for three-phase balanced and unbalanced sags
Author :
Bollen, Math H J ; Zhang, Lidong D.
Author_Institution :
Dept. of Electr. Power Eng., Chalmers Univ. of Technol., Goteborg, Sweden
Volume :
36
Issue :
3
fYear :
2000
Firstpage :
904
Lastpage :
910
Abstract :
Adjustable-speed drives are the type of equipment most sensitive to voltage sags. This paper analyzes the behavior of three-phase AC adjustable-speed drives during balanced and unbalanced sags. Emphasis is placed on the DC-bus voltage and on the drop in speed, both assuming that the drive will not trip. By using a previously introduced classification of three-phase unbalanced sags, voltage-tolerance curves are obtained for AC adjustable-speed drives. The conclusion from the analysis is that voltage sags due to three-phase faults are a serious problem for adjustable-speed drives. However, single-phase and phase-to-phase faults, causing the majority of voltage sags, can be tolerated by adding a relatively small amount of DC-bus capacitance
Keywords :
AC motor drives; machine theory; power supply quality; power system faults; variable speed drives; AC adjustable-speed drives; single-phase faults; three-phase balanced sags; three-phase faults; three-phase unbalanced sags; voltage sags; voltage tolerance analysis; Capacitors; Industrial power systems; Power engineering and energy; Power quality; Power system analysis computing; Power system modeling; Pulse width modulation; Rectifiers; Variable speed drives; Voltage fluctuations;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/28.845069
Filename :
845069
Link To Document :
بازگشت