DocumentCode :
1342445
Title :
Determination of Metal Contaminants Using Automated In-Situ Metrology in Semiconductor Cleaning Process
Author :
Lee, J.S. ; Jun, P.K. ; Lim, H.B.
Author_Institution :
Dept. of Chem., Dankook Univ., Yongin, South Korea
Volume :
11
Issue :
5
fYear :
2011
fDate :
5/1/2011 12:00:00 AM
Firstpage :
1120
Lastpage :
1128
Abstract :
This paper reports development of an in-situ metrology tool for monitoring metal contaminants existing in the semiconductor wafer cleaning process. Simultaneous detection of aluminum and transition metals at different wavelengths without significant interferences was made possible spectroscopically, using a mixture of 4-2- (pyridylazo) resorcinol and eriochrome cyanine red chelating reagents. This novel technology and apparatus designed for the fully automated in-situ metrology system enabled quantitative analysis of metal contaminants, even at sub-ppb concentrations. The metal monitoring technology is expected to be highly useful not only in semiconductor fabrication but also in several other industrial and academic fields.
Keywords :
integrated circuit manufacture; surface cleaning; surface contamination; wafer-scale integration; aluminum metal; automated insitu metrology; metal contaminant determination; metal contaminant monitoring; metal monitoring technology; quantitative analysis; red chelating reagents; semiconductor fabrication; semiconductor wafer cleaning process; transition metal; Aluminum; chelating reagent; in-situ metrology; instrumental analysis; light spectroscopy; mass spectrometry; metal complex; semiconductor; transition metal; wet cleaning chemical;
fLanguage :
English
Journal_Title :
Sensors Journal, IEEE
Publisher :
ieee
ISSN :
1530-437X
Type :
jour
DOI :
10.1109/JSEN.2010.2083648
Filename :
5594606
Link To Document :
بازگشت