• DocumentCode
    1342686
  • Title

    Induced Voltage Calculation in Electric Traction Systems: Simplified Methods, Screening Factors, and Accuracy

  • Author

    Mariscotti, Andrea

  • Author_Institution
    Dept. of Naval Archit. & Electr. Eng., Univ. of Genova, Genova, Italy
  • Volume
    12
  • Issue
    1
  • fYear
    2011
  • fDate
    3/1/2011 12:00:00 AM
  • Firstpage
    201
  • Lastpage
    210
  • Abstract
    In modern electric traction systems, the calculation of induced voltage on internal and external conductors is always required for both interference and people and equipment safety. The International Telegraph and Telephone Consultative Committee (CCITT) method is based on simplified relationships, which are integrated by suitable screening factors (representing and hiding the traction system complexity). Focus is on the determination of these factors and the accuracy, which are evaluated with simulation and experimental data. The considered systems are rail return, return conductor, and autotransformer (AT) 2 × 25-kV traction systems with victim cables of various lengths; the influence of the most relevant electric parameters (soil resistivity and conductance to earth of the return circuit conductors) is considered. The results confirm the relevance of the conductance to earth and of the position of the current injection point. The induced voltage is approximately proportional to the length, with a slight increase for shorter victim cables. The calculated AT screening factor is always smaller than the values suggested by the standards by a factor of 2 in the worst case. For the influence of separation of the inducing and victim circuits, the adopted methods agree in finding a critical distance around 6-8 m; at larger distances, CCITT values are slightly optimistic. Measured results confirm that the CCITT coefficients are all conservative by a factor of 2-4 (except the AT coefficient for total length exposure), whereas the multiconductor transmission line (MTL) results agree with a worst-case margin of 13%.
  • Keywords
    electric vehicles; railway electrification; traction; AT screening factor; CCITT method; International Telegraph and Telephone Consultative Committee method; autotransformer traction systems; current injection point; electric traction systems; induced voltage calculation; multiconductor transmission line; rail return; return conductor; victim cables; victim circuits; Electromagnetic induction; electromagnetic reactive interference; guideway transportation power systems; power distribution electromagnetic interference;
  • fLanguage
    English
  • Journal_Title
    Intelligent Transportation Systems, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1524-9050
  • Type

    jour

  • DOI
    10.1109/TITS.2010.2076327
  • Filename
    5594642