DocumentCode
1344799
Title
Silicon tracking at high luminosity colliders
Author
Seiden, Abraham
Author_Institution
Inst. for Particle Phys., California Univ., Santa Cruz, CA, USA
Volume
44
Issue
3
fYear
1997
fDate
6/1/1997 12:00:00 AM
Firstpage
615
Lastpage
621
Abstract
Future applications of silicon detectors at high luminosity colliders envision their use after fluences equivalent to 1014-1015 minimum ionizing particles/cm2 (MIP/cm2). This requires facing a number of special problems: large bias voltages on the detector, large leakage currents, and thermal instabilities. We present some of the relevant results on these problems as well as a brief review of some of the presently planned detectors
Keywords
silicon radiation detectors; Si; Si detectors; Si tracking; bias voltages; high luminosity colliders; leakage currents; thermal instabilities; Current measurement; Detectors; Face detection; Leak detection; Leakage current; Particle measurements; Particle tracking; Silicon; Trajectory; Voltage;