DocumentCode :
1344846
Title :
A method for reduction of parallax broadening in gas-based position sensitive detectors
Author :
Rehak, P. ; Smith, G.C. ; Yu, B.
Author_Institution :
Brookhaven Nat. Lab., Upton, NY, USA
Volume :
44
Issue :
3
fYear :
1997
fDate :
6/1/1997 12:00:00 AM
Firstpage :
651
Lastpage :
655
Abstract :
A description is given of the principle and experimental verification of a new method which significantly reduces broadening of the position response, due to parallax, for radiation incident on a detector at finite angles of incidence. The technique, which can be implemented in gas-based position-sensitive detectors with planar geometry, substantially improves position resolution for scattering experiments using X-rays and neutrons, and will permit larger angular coverage than has previously been possible. An improvement of nearly a factor four in rms position resolution is predicted, which is confirmed by measurements using a gas proportional X-ray detector with delay-line position encoding
Keywords :
X-ray detection; multiwire proportional chambers; position sensitive particle detectors; proportional counters; X-rays; angular coverage; delay-line position encoding; gas proportional X-ray detector; gas-based position sensitive detectors; neutrons; parallax broadening; planar geometry; position resolution; Delay; Encoding; Geometry; Neutrons; Position measurement; Position sensitive particle detectors; Radiation detectors; X-ray detection; X-ray detectors; X-ray scattering;
fLanguage :
English
Journal_Title :
Nuclear Science, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9499
Type :
jour
DOI :
10.1109/23.603727
Filename :
603727
Link To Document :
بازگشت