• DocumentCode
    1345435
  • Title

    Feasibility of tomography with unknown view angles

  • Author

    Basu, Samit ; Bresler, Yoram

  • Author_Institution
    Gen. Electr. Corp. Res. & Dev. Center, Niskayuna, NY, USA
  • Volume
    9
  • Issue
    6
  • fYear
    2000
  • fDate
    6/1/2000 12:00:00 AM
  • Firstpage
    1107
  • Lastpage
    1122
  • Abstract
    In the standard two-dimensional (2-D) parallel beam tomographic formulation, it is generally assumed that the angles at which the projections were acquired are known. We have previously demonstrated, however, that under fairly mild conditions these view angles can be uniquely recovered from the projections themselves. We address the question of reliability of such solutions to the angle recovery problem using moments of the projections. We demonstrate that under mild conditions, the angle recovery problem has unique solutions and is stable with respect to perturbations in the data. Furthermore, we determine the Cramer-Rao lower bounds on the variance of the estimates of the angles when the projection are corrupted by additive Gaussian noise. We also treat the case in which each projection is shifted by some unknown amount which must be jointly estimated with the view angles. Motivated by the stability results and relatively small values of the error bounds, we construct a simple algorithm to approximate the ML estimator and demonstrate that the problem can be feasibly solved in the presence of noise. Simulations using this simple estimator on a variety of phantoms show excellent performance at low to moderate noise levels, essentially achieving the Cramer-Rao bounds
  • Keywords
    Gaussian noise; computerised tomography; error analysis; maximum likelihood estimation; stability; 2D parallel beam tomographic formulation; Cramer-Rao lower bounds; ML estimator approximation; additive Gaussian noise; angle recovery problem; data perturbations stability; error bounds; noise levels; performance; phantoms; projection moments; reliability; simulations; stability results; tomography; unknown view angles; Additive noise; Biomedical imaging; Computational modeling; Gaussian noise; Image reconstruction; Magnetic resonance imaging; Maximum likelihood estimation; Stability; Tomography; Two dimensional displays;
  • fLanguage
    English
  • Journal_Title
    Image Processing, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1057-7149
  • Type

    jour

  • DOI
    10.1109/83.846252
  • Filename
    846252