• DocumentCode
    1345861
  • Title

    Diagnostic ultrasound tooth imaging using fractional fourier transform

  • Author

    Harput, Sevan ; Evans, Tony ; Bubb, Nigel ; Freear, Steven

  • Author_Institution
    Ultrasound Group, Univ. of Leeds, Leeds, UK
  • Volume
    58
  • Issue
    10
  • fYear
    2011
  • fDate
    10/1/2011 12:00:00 AM
  • Firstpage
    2096
  • Lastpage
    2106
  • Abstract
    An ultrasound contact imaging method is proposed to measure the enamel thickness in the human tooth. A delay-line transducer with a working frequency of 15 MHz is chosen to achieve a minimum resolvable distance of 400 μm in human enamel. To confirm the contact between the tooth and the transducer, a verification technique based on the phase shift upon reflection is used. Because of the high attenuation in human teeth, linear frequency-modulated chirp excitation and pulse compression are exploited to increase the penetration depth and improve the SNR. Preliminary measurements show that the enamel-dentin boundary creates numerous internal reflections, which cause the applied chirp signals to interfere arbitrarily. In this work, the fractional Fourier transform (FrFT) is employed for the first time in dental imaging to separate chirp signals overlapping in both time and frequency domains. The overlapped chirps are compressed using the FrFT and matched filter techniques. Micro-computed tomography is used for validation of the ultrasound measurements for both techniques. For a human molar, the thickness of the enamel layer is measured with an average error of 5.5% after compressing with the FrFT and 13.4% after compressing with the matched filter based on the average speed of sound in human teeth.
  • Keywords
    Fourier transforms; biomedical transducers; biomedical ultrasonics; computerised tomography; dentistry; diagnostic radiography; matched filters; medical image processing; pulse compression; applied chirp signals; delay-line transducer; diagnostic ultrasound tooth imaging; enamel-dentin boundary; fractional Fourier transform; frequency 15 MHz; human enamel; human teeth; human tooth; internal reflections; linear frequency-modulated chirp excitation; matched filter techniques; microcomputed tomography; penetration depth; phase shift; pulse compression; ultrasound contact imaging method; ultrasound measurements; Acoustics; Chirp; Dentistry; Imaging; Teeth; Transducers; Ultrasonic imaging; Algorithms; Dental Enamel; Fourier Analysis; Humans; Molar; Phantoms, Imaging; Signal Processing, Computer-Assisted; Signal-To-Noise Ratio; Transducers; Ultrasonography; X-Ray Microtomography;
  • fLanguage
    English
  • Journal_Title
    Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0885-3010
  • Type

    jour

  • DOI
    10.1109/TUFFC.2011.2059
  • Filename
    6039999