• DocumentCode
    1346054
  • Title

    Performance comparison of small form factor fiber optic connectors

  • Author

    Trewhella, Jean M. ; DeCusatis, Casimer M. ; Fox, John

  • Author_Institution
    IBM Thomas J. Watson Res. Center, Yorktown Heights, NY, USA
  • Volume
    23
  • Issue
    2
  • fYear
    2000
  • fDate
    5/1/2000 12:00:00 AM
  • Firstpage
    188
  • Lastpage
    196
  • Abstract
    A comparison of small form factor (SFF) fiber optic connectors is presented for LC, MT-RJ, SC-DC, and VF-45. Multimode jumper cables were tested using industry standard test procedures and bench marked against the industry standard SC Duplex connector. Initial loss data as well as stress testing was performed. Variations were found in the performance of the connectors types and between connectors of the same type from different suppliers. In some cases the connectors out performed the SC Duplex on some tests but no connectors out performed the SC Duplex on all tests with the mechanical stress tests of axial and off-axial pull being the most difficult to exceed. These connectors are rapidly developing and are at different levels of maturity but none of them tested out to be a fully mature replacement for the SC Duplex connector yet
  • Keywords
    environmental testing; optical cables; optical fibre couplers; optical fibre losses; optical fibre testing; SC Duplex connector; alignment; axial pull; ceramic ferrules; dual connect; loss data; multimode jumper cables; off-axial pull; performance comparison; quad connect; small form factor fiber optic connectors; stress testing; thermal cycling; Connectors; Costs; Manufacturing; Optical design; Optical fiber devices; Optical fibers; Performance evaluation; Stress; Testing; Transceivers;
  • fLanguage
    English
  • Journal_Title
    Advanced Packaging, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1521-3323
  • Type

    jour

  • DOI
    10.1109/6040.846632
  • Filename
    846632