DocumentCode
1346682
Title
Enhanced Sensitivity of SAW-Based Pirani Vacuum Pressure Sensor
Author
Singh, Kanwar J. ; Elmazria, Omar ; Sarry, Frederic ; Nicolay, Pascal ; Ghoumid, Kamal ; Belgacem, Brahim ; Mercier, Denis ; Bounouar, Julien
Author_Institution
Inst. Jean Lamour, Nancy Univ., Nancy, France
Volume
11
Issue
6
fYear
2011
fDate
6/1/2011 12:00:00 AM
Firstpage
1458
Lastpage
1464
Abstract
The authors have already presented a novel surface acoustic wave device for vacuum pressure measurement by employing a piezoelectric substrate that has a high value of temperature coefficient of frequency. Frequency-shift measurements as a function of vacuum pressure can be used to extract information about the pressure sensitivity of the device. In this paper, we report that the deposition of an aluminum thin-film layer and rise in the sensor´s operating temperature significantly improve the sensitivity of the device. The results are crucial for improving the lower limit of the vacuum pressure measurement, which currently stands around 10-3 Pa.
Keywords
pressure sensors; surface acoustic wave sensors; SAW-based Pirani vacuum pressure sensor; frequency shift measurement; piezoelectric substrate; vacuum pressure measurement; Lithium niobate; Sensitivity; Substrates; Surface acoustic wave devices; Surface acoustic waves; Temperature measurement; Temperature sensors; Acoustic devices; frequency response; pressure measurements; sensitivity;
fLanguage
English
Journal_Title
Sensors Journal, IEEE
Publisher
ieee
ISSN
1530-437X
Type
jour
DOI
10.1109/JSEN.2010.2086055
Filename
5598508
Link To Document