DocumentCode
1346715
Title
The effect of machine impedances on the voltage unbalance of 3-phase synchronous generators
Author
Hardman, T. F.
Author_Institution
Westinghouse Electric Corporation, Lima, Ohio
Volume
74
Issue
6
fYear
1956
Firstpage
467
Lastpage
471
Abstract
IN COMMON use today are many 3-phase 4-wire electric systems that operate primarily with single-phase line-to-neutral loads. Quite often on these systems it is found impractical to distribute the single-phase loads so that the power supply operates into a balanced 3-phase system. A-c power systems on present-day aircraft typify this condition.
Keywords
Aircraft; Equations; Generators; Impedance; Mathematical model; Regulators; Voltage control;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
Publisher
ieee
ISSN
0097-2185
Type
jour
DOI
10.1109/TAI.1956.6367131
Filename
6367131
Link To Document