• DocumentCode
    1346793
  • Title

    Methods of measuring arc-drop voltage on mercury-arc rectifiers

  • Author

    Winograd, Harold ; Lawton, E. William

  • Author_Institution
    Allis-Chalmers Manufacturing Company, Milwaukee, Wis.
  • Volume
    75
  • Issue
    1
  • fYear
    1956
  • fDate
    3/1/1956 12:00:00 AM
  • Firstpage
    43
  • Lastpage
    48
  • Abstract
    THE over-all efficiency of a mercury-arc rectifier unit is determined by the segregated loss method. The losses in the component parts of the unit ¿ the rectifier transformer, rectifier, and its auxiliaries ¿ are measured separately, and the efficiency is calculated. The methods used for measuring the losses are specified in the American Standards Association (ASA) Standard for Pool Cathode Mercury-Arc Power Converters.1 This method is used for determining the efficiency, instead of measuring the power input and output of the unit, for two reasons: 1. The losses constitute a relatively small percentage of the unit rating (approximately 5 per cent for a d-c output voltage of 600 volts) and can be determined more accurately by individual loss measiuements. 2. To set up a complete rectifier unit in the factory for a full-load test would be costly and is not always pcactical, because of the limitations of available testing facilities.
  • Keywords
    Anodes; Electron tubes; Loss measurement; Rectifiers; Standards; Voltage measurement; Wattmeters;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2185
  • Type

    jour

  • DOI
    10.1109/TAI.1956.6367146
  • Filename
    6367146