DocumentCode :
1346901
Title :
Parallel operation of aircraft A-C generators: Reactive load division and selective protection
Author :
Kahle, H. A.
Author_Institution :
Jack & Heintz, Inc., Cleveland, Ohio
Volume :
75
Issue :
3
fYear :
1956
fDate :
7/1/1956 12:00:00 AM
Firstpage :
175
Lastpage :
181
Abstract :
THE parallel operation, as in today´s aircraft, of electric a-c generators supplying a common bus requires that the total system load be divided equally among the paralleled generators. Real load and RL (reactive load) division are regulated through the speed and voltage regulator respectively. This paper concerns RL division only and the co-ordination of a high-phase voltage-sensing regulator with the RL sharing circuit and over-voltage and undervoltage protection.
Keywords :
Current transformers; Equations; Generators; Magnetic circuits; Rectifiers; Regulators; Voltage control;
fLanguage :
English
Journal_Title :
American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
Publisher :
ieee
ISSN :
0097-2185
Type :
jour
DOI :
10.1109/TAI.1956.6367167
Filename :
6367167
Link To Document :
بازگشت