• DocumentCode
    1346901
  • Title

    Parallel operation of aircraft A-C generators: Reactive load division and selective protection

  • Author

    Kahle, H. A.

  • Author_Institution
    Jack & Heintz, Inc., Cleveland, Ohio
  • Volume
    75
  • Issue
    3
  • fYear
    1956
  • fDate
    7/1/1956 12:00:00 AM
  • Firstpage
    175
  • Lastpage
    181
  • Abstract
    THE parallel operation, as in today´s aircraft, of electric a-c generators supplying a common bus requires that the total system load be divided equally among the paralleled generators. Real load and RL (reactive load) division are regulated through the speed and voltage regulator respectively. This paper concerns RL division only and the co-ordination of a high-phase voltage-sensing regulator with the RL sharing circuit and over-voltage and undervoltage protection.
  • Keywords
    Current transformers; Equations; Generators; Magnetic circuits; Rectifiers; Regulators; Voltage control;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2185
  • Type

    jour

  • DOI
    10.1109/TAI.1956.6367167
  • Filename
    6367167