DocumentCode
1346901
Title
Parallel operation of aircraft A-C generators: Reactive load division and selective protection
Author
Kahle, H. A.
Author_Institution
Jack & Heintz, Inc., Cleveland, Ohio
Volume
75
Issue
3
fYear
1956
fDate
7/1/1956 12:00:00 AM
Firstpage
175
Lastpage
181
Abstract
THE parallel operation, as in today´s aircraft, of electric a-c generators supplying a common bus requires that the total system load be divided equally among the paralleled generators. Real load and RL (reactive load) division are regulated through the speed and voltage regulator respectively. This paper concerns RL division only and the co-ordination of a high-phase voltage-sensing regulator with the RL sharing circuit and over-voltage and undervoltage protection.
Keywords
Current transformers; Equations; Generators; Magnetic circuits; Rectifiers; Regulators; Voltage control;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
Publisher
ieee
ISSN
0097-2185
Type
jour
DOI
10.1109/TAI.1956.6367167