DocumentCode :
1347685
Title :
Fault tolerant ac-dc-ac single-phase to three-phase converter
Author :
dos Santos, Euzeli Cipriano ; Jacobina, Cursino B. ; Dias, Jose A. A. ; Rocha, Nady
Author_Institution :
Dept. de Eng. Eletr., Univ. Fed. de Campina Grande, Campina Grande, Brazil
Volume :
4
Issue :
9
fYear :
2011
fDate :
11/1/2011 12:00:00 AM
Firstpage :
1023
Lastpage :
1031
Abstract :
A fault tolerant system considering a single-phase to three-phase power conversion has been proposed in this work. Two kinds of failures occurring in the converter power devices, open-circuit and short-circuit, can be compensated by the proposed strategy. The fault compensation is achieved by reconfiguring the power converter topology with the help of isolation and connection devices. These devices are used to redefine the post-fault converter topology. A proposed control strategy allows to keep the post-fault topology operating at same power rate of the pre-fault topology. Simulated and experimental results demonstrate the validity of the proposed systems.
Keywords :
AC-DC power convertors; DC-AC power convertors; compensation; fault tolerance; AC-DC-AC single-phase-to-three-phase converter; connection device; control strategy; fault compensation; fault tolerant system; isolation device; post-fault converter topology; power converter topology; pre-fault topology;
fLanguage :
English
Journal_Title :
Power Electronics, IET
Publisher :
iet
ISSN :
1755-4535
Type :
jour
DOI :
10.1049/iet-pel.2010.0342
Filename :
6042382
Link To Document :
بازگشت