What went wrong IV: The Browns Ferry incident: Seeking air leaks with a candle at the TVA´s nuclear power plant, a worker found much more
Author
Kaplan, G.
Volume
13
Issue
10
fYear
1976
Firstpage
55
Lastpage
64
Abstract
The candle flame that touched off the most severe fire in the history of US commercial nuclear power generation was being used by a plant worker to detect possible flaws in a feature designed to control the spread of fires. The incident is chronicled and lessons deduced from it are outlined.
Keywords
fires; nuclear power stations; Browns Ferry; fire; nuclear power generation; Buildings; Cable TV; Cable insulation; Fires; Inductors; Standards; Valves;