DocumentCode
135289
Title
A verification experiment for comparing digital and analog measurements of time-varying harmonics
Author
Carvalho, T.C.O. ; Cuk, V. ; Duque, C.A. ; Silveira, Paulo M. ; Severo Mendes, M.A. ; Ribeiro, P.F.
Author_Institution
Centro Fed. de Educ. Tecnol., Leopoldina, Brazil
fYear
2014
fDate
27-31 July 2014
Firstpage
1
Lastpage
5
Abstract
This paper presents laboratory results on the behavior of time-varying harmonics caused by an electronic converter under a voltage sag and load variations in order to demonstrate the validity of digital time-frequency decomposition methods. A filter centered on the 7th harmonic is used to capture the analog signal and its output is compared with the corresponding harmonic derived by digital signal processing techniques for physical and analog verification purposes. This approach allows engineers to look into the transient phenomena through the observation of the behavior of time-varying harmonics for a better understanding of associated causes of the signal characteristics.
Keywords
channel bank filters; digital filters; discrete Fourier transforms; power supply quality; power system harmonics; signal processing; digital filter bank; digital signal processing; digital time-frequency decomposition method; electronic converter; sliding window recursive DFT; time-varying harmonic decomposition; voltage sag; Digital filters; Filter banks; Harmonic analysis; Power harmonic filters; Voltage fluctuations; Filter Bank; Harmonic distortion; Power Quality; Short Time Fourier Transform; Time-frequency methods; Time-varying harmonics;
fLanguage
English
Publisher
ieee
Conference_Titel
PES General Meeting | Conference & Exposition, 2014 IEEE
Conference_Location
National Harbor, MD
Type
conf
DOI
10.1109/PESGM.2014.6939232
Filename
6939232