• DocumentCode
    1354770
  • Title

    Thermal voltage converters for accurate voltage measurements to 30 megacycles per second

  • Author

    Hermach, F. L. ; Williams, E. S.

  • Author_Institution
    National Bureau of Standards, Washington, D. C.
  • Volume
    79
  • Issue
    3
  • fYear
    1960
  • fDate
    7/1/1960 12:00:00 AM
  • Firstpage
    200
  • Lastpage
    206
  • Abstract
    Thermal voltage converters, each consisting of a resistor in series with a thermoelement in a coaxial line, have been developed for measurements of rms voltages of 1 to 200 volts at frequencies from 3 cps (cycles per second) to 30 mc (megacycles). An accuracy of 0.1% or better may be obtained by a-c-d-c transfer techniques up to at least 10 mc and 0.2% at 30 mc.
  • Keywords
    Connectors; Equations; Frequency conversion; Heating; Resistance; Resistors; Voltage measurement;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2452
  • Type

    jour

  • DOI
    10.1109/TCE.1960.6368573
  • Filename
    6368573