  • Title

    On exponential growth [of gas breakdown]

  • Author

    McAllister, I.W.

  • Author_Institution
    Phys. Lab. II, Tech. Univ. of Denmark, Lyngby, Denmark
  • Volume
    26
  • Issue
    3
  • fYear
    1991
  • fDate
    6/1/1991 12:00:00 AM
  • Firstpage
    378
  • Lastpage
    379
  • Abstract
    The agreement obtained between measured breakdown voltages and predicted breakdown values is frequently used as a means of assessing the validity of the theory/model in question. However, owing to the mathematical nature of exponential growth, it is easy to formulate a criterion that provides acceptable breakdown values, although the criterion may contain totally unrealistic features. An example from the work of A. Pedersen (1989) showing unrestricted exponential growth in SF 6 is used to highlight the insensitivity of breakdown voltages with respect to modeling
  • Keywords
    electric breakdown of gases; gaseous insulation; sulphur compounds; SF6; breakdown values; breakdown voltages; exponential growth; modeling; Atmospheric modeling; Breakdown voltage; Dielectrics and electrical insulation; Electric breakdown; Electrons; Engineering profession; Laboratories; Pain; Physics; Predictive models;
  • fLanguage
    English
  • Journal_Title
    Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9367
  • Type

    jour

  • DOI
    10.1109/14.85106
  • Filename
    85106