• DocumentCode
    1356958
  • Title

    Optimum electrical PD test method for large capacitors

  • Author

    Boggs, S.A. ; Bommakanti, R.G. ; Baker, D.

  • Author_Institution
    Underground Syst. Inc., Armonk, NY, USA
  • Volume
    26
  • Issue
    3
  • fYear
    1991
  • fDate
    6/1/1991 12:00:00 AM
  • Firstpage
    479
  • Lastpage
    486
  • Abstract
    The optimum method for electrical partial discharge testing of large capacitors, including the effects of internal inductance, is determined. The results indicate that internal inductance does not adversely affect detection sensitivity if the detection impedance is made equal to the critical damping resistance. This has the advantage of providing a nonresonant waveform which can be detected in a near-optimum manner using a simple low-pass filter
  • Keywords
    capacitors; electronic equipment testing; partial discharges; critical damping resistance; detection impedance; detection sensitivity; electrical PD test method; internal inductance; large capacitors; low-pass filter; nonresonant waveform; partial discharge testing; Capacitance; Capacitors; Distortion measurement; Electrical resistance measurement; Impedance; Inductance; Partial discharges; Pulse measurements; Resonance; System testing;
  • fLanguage
    English
  • Journal_Title
    Electrical Insulation, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9367
  • Type

    jour

  • DOI
    10.1109/14.85120
  • Filename
    85120