• DocumentCode
    1359402
  • Title

    Discussion on “electrical control of a large mine hoist” (Cheney), Pittsburgh, Pa., April 27, 1912. (see proceedings for March, 1912. (continued from November, 1912, proceedings, page 2060)

  • Volume
    31
  • Issue
    12
  • fYear
    1912
  • Firstpage
    2418
  • Lastpage
    2419
  • Abstract
    Answering the criticism of the high slip (and consequent low efficiency) at full speed, Mr. Cheney stated that where the period of full speed running is long it will be advantageous to short-circuit the motor secondary at the brushes by means of switches. It is extremely doubtful whether any simple and wholly reliable method can be obtained whereby contactors (or other forms of switches) can be used to short-circuit the rheostat automatically when the liquid rises to its maximum level.
  • Keywords
    Brushes; Contactors; Fluctuations; Liquids; Resistance; Torque;