DocumentCode
1364568
Title
An Accurate Time-Domain Procedure for Harmonics and Interharmonics Detection
Author
Chang, Gary W. ; Chen, Cheng-I
Author_Institution
Dept. of Electr. Eng., Nat. Chung Cheng Univ., Chiayi, Taiwan
Volume
25
Issue
3
fYear
2010
fDate
7/1/2010 12:00:00 AM
Firstpage
1787
Lastpage
1795
Abstract
Frequency is an important indicator for the quality of electric power. Accurate spectral decompositions rely much on the correct identification of frequencies of the measured signals. An efficient procedure that includes a high-resolution Prony-based method in conjunction with the downsampling technique for harmonics and interharmonics detection of the measured power signal is proposed in this paper. It is shown that even when two or more closely adjacent spectral lines are present, the proposed method can precisely detect the harmonic and interharmonic components. The performance of the proposed method is validated by testing the simulated and actual measured power signals. Results are compared with those obtained by fast Fourier transform with and without synchronization, IEC subgrouping method, and other commonly used linear prediction approaches adopted in the Prony´s method. It shows that the proposed method is more accurate on the detection of harmonics and interharmonics with high resolution.
Keywords
fast Fourier transforms; power supply quality; power system harmonics; synchronisation; IEC subgrouping method; adjacent spectral lines; downsampling technique; electric power quality; fast Fourier transform; high-resolution Prony-based method; interharmonics detection; linear prediction; spectral decompositions; synchronization; time-domain procedure; Downsampling; Prony´s method; harmonics; interharmonics; singular value decomposition (SVD);
fLanguage
English
Journal_Title
Power Delivery, IEEE Transactions on
Publisher
ieee
ISSN
0885-8977
Type
jour
DOI
10.1109/TPWRD.2009.2037230
Filename
5361340