DocumentCode :
1364754
Title :
Adaptive AR modeling of nonstationary time series by means of Kalman filtering
Author :
Arnold, Matthias ; Milner, X.H.R. ; Witte, Herbert ; Bauer, Reinhard ; Braun, Christoph
Author_Institution :
Inst. of Med. Stat., Comput. Sci. & Documentation, Friedrich-Schiller-Univ., Jena, Germany
Volume :
45
Issue :
5
fYear :
1998
fDate :
5/1/1998 12:00:00 AM
Firstpage :
553
Lastpage :
562
Abstract :
An adaptive on-line procedure is presented for autoregressive (AR) modeling of nonstationary multivariate time series by means of Kalman filtering. The parameters of the estimated time-varying model can be used to calculate instantaneous measures of linear dependence. The usefulness of the procedures in the analysis of physiological signals is discussed in two examples: first, in the analysis of respiratory movement, heart rate fluctuation, and blood pressure, and second, in the analysis of multichannel electroencephalogram (EEG) signals. It was shown for the first time that in intact animals the transition from a normoxic to a hypoxic state requires tremendous short-term readjustment of the autonomic cardiac-respiratory control. An application with experimental EEG data supported observations that the development of coherences among cell assemblies of the brain is a basic element of associative learning or conditioning.
Keywords :
adaptive Kalman filters; adaptive signal processing; biomechanics; blood pressure measurement; electroencephalography; medical signal processing; physiological models; time series; Kalman filtering; adaptive autoregressive modeling; associative learning; autonomic cardiac-respiratory control; brain cell assemblies coherencies; conditioning; experimental EEG data; heart rate fluctuation; hypoxic state; multichannel signals analysis; nonstationary time series; normoxic state; respiratory movement analysis; Adaptive filters; Blood pressure; Brain modeling; Electroencephalography; Filtering; Fluctuations; Heart rate; Kalman filters; Parameter estimation; Signal analysis; Adaptation, Physiological; Adult; Algorithms; Analysis of Variance; Animals; Animals, Newborn; Anoxia; Conditioning, Operant; Electrocardiography; Electroencephalography; Female; Heart Rate; Humans; Linear Models; Male; Models, Biological; Multivariate Analysis; Periodicity; Reference Values; Reproducibility of Results; Respiration; Signal Processing, Computer-Assisted; Stochastic Processes; Swine;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/10.668741
Filename :
668741
Link To Document :
بازگشت