Prediction of starting performance of PM motors by DC decay testing method
Author :
Yamamoto, Shu ; Ara, Takahiro ; Oda, Shoichi ; Matsuse, Kouki
Author_Institution :
Dept. of Electr. Eng., Polytech.. Univ., Kanagawa, Japan
Volume :
36
Issue :
4
fYear :
2000
Firstpage :
1053
Lastpage :
1060
Abstract :
This paper presents a method to predict the direct- and quadrature-axes operational impedances and starting performance of permanent-magnet (PM) motors by a simple standstill response testing method using a small-capacity DC power supply unit. In this method, not only the starting performance but also the direct- and quadrature-axes synchronous machine constants (synchronous, transient, and subtransient reactances) and equivalent circuit constants are calculated. This proposed strategy, tentatively named the DC decay testing method, is carried out on a 3.7-kW 200-V 22. A 100-Hz four-pole interior PM motor with a damper winding. The results measured by on-load tests and those predicted by the proposed method on starting performance demonstrate the validity and usefulness of the proposed method
Keywords :
electric impedance; equivalent circuits; machine testing; machine theory; machine windings; permanent magnet motors; starting; synchronous motors; 100 Hz; 200 V; 22 A; 3.7 kW; DC decay testing method; DC power supply unit; PM motors; damper winding; direct-axis operational impedance; equivalent circuit constants; on-load tests; quadrature-axis operational impedance; standstill response testing method; starting performance prediction; synchronous machine constants; Circuit testing; Current measurement; DC motors; Equivalent circuits; Impedance; Power supplies; Rotors; Synchronous machines; Synchronous motors; Torque;
fLanguage :
English
Journal_Title :
Industry Applications, IEEE Transactions on
Publisher :
ieee
ISSN :
0093-9994
Type :
jour
DOI :
10.1109/28.855960