DocumentCode :
1366312
Title :
Finite element analysis of cardiac defibrillation current distributions
Author :
Sepulveda, Nestor G. ; Wikswo, John P., Jr. ; Echt, Debra S.
Author_Institution :
Dept. of Phys. & Astron., Vanderbilt Univ., Nashville, TN, USA
Volume :
37
Issue :
4
fYear :
1990
fDate :
4/1/1990 12:00:00 AM
Firstpage :
354
Lastpage :
365
Abstract :
A two-dimensional finite element model of the canine heart and thorax developed to examine different aspects of the distribution of current through cardiac tissue during defibrillation is discussed. This model allows comparison of the various electrode configurations for the implantable cardioverter/defibrillator. Since the electrical criteria for predicting defibrillation thresholds are not known, defibrillation energy in dogs was measured to determine the voltages to apply to the model for calculating current distribution. Analyzing isopotential contours, current lines, power distributions, current lines, power distributions, current density histograms, and cumulative current distributions allowed the critical fraction and threshold current density for defibrillation to be estimated, various electrode configurations to be compared, and the sensitivity of the defibrillation threshold to electrode position, patch size, and tissue conductivity to be assessed. It was found that blood can shunt defibrillation current away from the myocardium, that myocardial tissue conductivity strongly affects the current distributions, and that epicardial patch size is more important than subcutaneous patch size.
Keywords :
bioelectric phenomena; current distribution; defibrillators; finite element analysis; physiological models; canine heart; canine thorax; cardiac defibrillation current distributions; cardiac tissue; critical fraction; cumulative current distributions; current density histograms; current lines; defibrillation threshold; electrode configurations; electrode position; implantable cardioverter/defibrillator; isopotential contours; myocardial tissue conductivity; patch size; power distributions; two-dimensional finite element model; Cardiac tissue; Conductivity; Current distribution; Defibrillation; Electrodes; Finite element methods; Heart; Myocardium; Power distribution; Thorax; Animals; Dogs; Electric Conductivity; Electric Countershock; Electrodes; Heart; Models, Cardiovascular;
fLanguage :
English
Journal_Title :
Biomedical Engineering, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9294
Type :
jour
DOI :
10.1109/10.52342
Filename :
52342
Link To Document :
بازگشت