DocumentCode
136945
Title
A novel LCD snubber for bifilar-wound permanent magnet synchronous motors
Author
Shi Qibiao ; Zhao Feng ; Wen Xuhui ; Wang Yongxing
Author_Institution
Inst. of Electr. Eng., Beijing, China
fYear
2014
fDate
Aug. 31 2014-Sept. 3 2014
Firstpage
1
Lastpage
4
Abstract
In this paper, the snubbers for bifilar-wound motors are investigated and a novel LCD snubber is proposed. The bifilar connection offers the benefit of high fault tolerant ability and requiring only low side power device which simplifies the design of inverter. However, high voltage is produced by the leakage between the two bifilar coils, causing the voltage press and the switching loss of the power switches to increase. Thus a snubber is necessary for a bifilar-wound motor. The proposed LCD snubber for bifilar-wound motor is analyzed and the design method is also given in details.
Keywords
invertors; permanent magnet motors; power semiconductor switches; snubbers; synchronous motors; LCD snubber; bifilar coils; bifilar connection; bifilar-wound motor; bifilar-wound permanent magnet synchronous motors; high fault tolerant ability; inverter; low side power device; power switches; switching loss; voltage press; Switches;
fLanguage
English
Publisher
ieee
Conference_Titel
Transportation Electrification Asia-Pacific (ITEC Asia-Pacific), 2014 IEEE Conference and Expo
Conference_Location
Beijing
Print_ISBN
978-1-4799-4240-4
Type
conf
DOI
10.1109/ITEC-AP.2014.6941193