• DocumentCode
    1369699
  • Title

    The effect of wheelchair handrim tube diameter on propulsion efficiency and force application (tube diameter and efficiency in wheelchairs)

  • Author

    Van Der Linden, Maríëtta L. ; Valent, Linda ; Veeger, H.E.J. ; van der Wonde, L.H.V.

  • Author_Institution
    Fac. of Human Movement Sci., Vrije Univ., Amsterdam, Netherlands
  • Volume
    4
  • Issue
    3
  • fYear
    1996
  • fDate
    9/1/1996 12:00:00 AM
  • Firstpage
    123
  • Lastpage
    132
  • Abstract
    To determine the optimum tube diameter of a standard handrim-propelled wheelchair, the effect of tube size and shape on physiological and kinetic parameters was studied. Six able-bodied male subjects performed two tests on a wheelchair ergometer. Tests were performed against work loads comparable to every day use and with two different handrim tube diameters, a handrim with an oval 25 by 30 mm diameter (LR) and one with an 18 mm diameter (SR). The large tube diameter (LR) yielded slightly but significantly lower values for the physiological parameters. Gross mechanical efficiency was on average 7% for the LR and 6.3% for the SR. No significant results were found for force application parameters related to the direction of the applied force or the torque by the hand onto the handrim surface. As technique parameters could not explain the higher mechanical efficiency (ME) when using the LR, it is suggested that hand grip constraints in the push phase (finger flexor activity) might be responsible. Another possible explanation is that with a better hand grip using LR, less stabilization by the larger muscle groups at the elbow and shoulder is needed. The measured technique parameters seem to be determined by geometric constraints of the arm and shoulder. The technique requirements resulting from the forced trajectory of the Propulsion movement are also likely to determine the technique parameters. Regarding the low mechanical efficiency of handrim propulsion, which is partly caused by the forced unfavorable trajectory of the hand, an alternative propulsion mechanism is suggested
  • Keywords
    biomechanics; design engineering; ergonomics; handicapped aids; 18 mm; 25 mm; 30 mm; able-bodied male subjects; force application; force application parameters; gross mechanical efficiency; kinetic parameters; optimum tube diameter; physiological parameters; propulsion efficiency; standard handrim-propelled wheelchair; technique parameters; tube diameter; wheelchair efficiency; wheelchair ergometer; wheelchair handrim tube diameter; work loads; Fingers; Kinetic theory; Muscles; Performance evaluation; Propulsion; Shape; Strontium; Testing; Torque; Wheelchairs;
  • fLanguage
    English
  • Journal_Title
    Rehabilitation Engineering, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    1063-6528
  • Type

    jour

  • DOI
    10.1109/86.536767