DocumentCode
1370776
Title
Lesion generation through ribs using histotripsy therapy without aberration correction
Author
Kim, Yohan ; Wang, Tzu-Yin ; Xu, Zhen ; Cain, Charles A.
Author_Institution
Dept. of Biomed. Eng., Univ. of Michigan, Ann Arbor, MI, USA
Volume
58
Issue
11
fYear
2011
fDate
11/1/2011 12:00:00 AM
Firstpage
2334
Lastpage
2343
Abstract
This study investigates the feasibility of using high-intensity pulsed therapeutic ultrasound, or histotripsy, to non-invasively generate lesions through the ribs. Histotripsy therapy mechanically ablates tissue through the generation of a cavitation bubble cloud, which occurs when the focal pressure exceeds a certain threshold. We hypothesize that histotripsy can generate precise lesions through the ribs without aberration correction if the main lobe retains its shape and exceeds the cavitation initiation threshold and the secondary lobes remain below the threshold. To test this hypothesis, a 750-kHz focused transducer was used to generate lesions in tissue-mimicking phantoms with and without the presence of rib aberrators. In all cases, 8000 pulses with 16 to 18 MPa peak rarefactional pressure at a repetition frequency of 100 Hz were applied without aberration correction. Despite the high secondary lobes introduced by the aberrators, high-speed imaging showed that bubble clouds were generated exclusively at the focus, resulting in well-confined lesions with comparable dimensions. Collateral damage from secondary lobes was negligible, caused by single bubbles that failed to form a cloud. These results support our hypothesis, suggesting that histotripsy has a high tolerance for aberrated fields and can generate confined focal lesions through rib obstacles without aberration correction.This study investigates the feasibility of using high-intensity pulsed therapeutic ultrasound, or histotripsy, to non-invasively generate lesions through the ribs. Histotripsy therapy mechanically ablates tissue through the generation of a cavitation bubble cloud, which occurs when the focal pressure exceeds a certain threshold. We hypothesize that histotripsy can generate precise lesions through the ribs without aberration correction if the main lobe retains its shape and exceeds the cavitation initiation threshold and the secondary lobes remain below the threshold. To test this hypo- hesis, a 750-kHz focused transducer was used to generate lesions in tissue-mimicking phantoms with and without the presence of rib aberrators. In all cases, 8000 pulses with 16 to 18 MPa peak rarefactional pressure at a repetition frequency of 100 Hz were applied without aberration correction. Despite the high secondary lobes introduced by the aberrators, high-speed imaging showed that bubble clouds were generated exclusively at the focus, resulting in well-confined lesions with comparable dimensions. Collateral damage from secondary lobes was negligible, caused by single bubbles that failed to form a cloud. These results support our hypothesis, suggesting that histotripsy has a high tolerance for aberrated fields and can generate confined focal lesions through rib obstacles without aberration correction.
Keywords
aberrations; biological tissues; biomedical transducers; biomedical ultrasonics; cavitation; cellular biophysics; patient treatment; aberration correction; cavitation bubble cloud; cavitation initiation threshold; collateral damage; frequency 100 Hz; frequency 750 kHz; high-intensity pulsed therapeutic ultrasound; high-speed imaging; histotripsy therapy; noninvasively generate lesions; rib aberrators; rib obstacles; secondary lobes; tissue-mimicking phantoms; Acoustics; Lesions; Medical treatment; Phantoms; Ribs; Transducers; Ultrasonic imaging; Dose-Response Relationship, Radiation; Humans; Organ Sparing Treatments; Phantoms, Imaging; Radiation Dosage; Radiation Injuries; Ribs; Ultrasonic Therapy;
fLanguage
English
Journal_Title
Ultrasonics, Ferroelectrics, and Frequency Control, IEEE Transactions on
Publisher
ieee
ISSN
0885-3010
Type
jour
DOI
10.1109/TUFFC.2011.2091
Filename
6071052
Link To Document