• DocumentCode
    1371264
  • Title

    A method of calculating current-limiter and fuse-clearing times in A-C systems

  • Author

    Caldwell, S. C. ; Jensen, L. E.

  • Author_Institution
    General Electric Company, Schenectady, N. Y.
  • Volume
    73
  • Issue
    5
  • fYear
    1954
  • Firstpage
    263
  • Lastpage
    267
  • Abstract
    When a fault occurs on an aircraft a-c system with voltage-regulated alternators, the short-circuit current goes through a transient period depending on the alternator-regulator characteristic. This transient period has been found to vary from several milliseconds to perhaps 300 milliseconds and, consequently, may have a considerable effect on fuse or current-limiter clearing times. This paper presents a method of calculating current-limiter or fuse-clearing times which includes the effect of this transient period. Results of calculations from this method are compared with laboratory tests demonstrating that the method has a reasonable degree of accuracy.
  • Keywords
    Aircraft; Equations; Feeds; Fuses; Generators; Resistance; Transient analysis;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2185
  • Type

    jour

  • DOI
    10.1109/TAI.1954.6371430
  • Filename
    6371430