DocumentCode
1371284
Title
Sensitivity requirements of reactive load division circuits in aircraft electric systems
Author
Sherrard, S. Emile
Author_Institution
Naval Research Laboratory, Washington, D. C.
Volume
73
Issue
5
fYear
1954
Firstpage
279
Lastpage
288
Abstract
Reactive load unbalance among paralleled generators is analyzed to relate the largest unbalance with the sensitivity of the reactive load division circuit employed in the regulators and with the regulation characteristics of the individual generator-exciter-regulator units. The maximum permissible sensitivity of the reactive load division circuit is found, from stability considerations, to be determined by the unsaturated synchronous reactance of the paralleled generators. The design of the reactive load division circuit is discussed from a system viewpoint.
Keywords
Current transformers; Equalizers; Generators; Rectifiers; Regulators; Sensitivity; Voltage control;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
Publisher
ieee
ISSN
0097-2185
Type
jour
DOI
10.1109/TAI.1954.6371433
Filename
6371433
Link To Document