DocumentCode
1371576
Title
Frequency response from experimental nonoscillatory transient-response data
Author
Thal-Larsen, H.
Author_Institution
University of California, Berkeley, Calif.
Volume
74
Issue
2
fYear
1955
fDate
5/1/1955 12:00:00 AM
Firstpage
109
Lastpage
114
Abstract
Curves are derived and presented which provide a ready means for approximating transfer functions with time constants up to three in number, and also dead time, from the experimental non-oscillatory transient response produced by a step change. The transfer function containing the time constants and dead time may be used to obtain the corresponding frequency response. These curves then are a graphical aid for converting transient response into frequency response.
Keywords
Copper; Corrosion; Frequency response; Steel; Transfer functions; Transient analysis; Transient response;