• DocumentCode
    1371576
  • Title

    Frequency response from experimental nonoscillatory transient-response data

  • Author

    Thal-Larsen, H.

  • Author_Institution
    University of California, Berkeley, Calif.
  • Volume
    74
  • Issue
    2
  • fYear
    1955
  • fDate
    5/1/1955 12:00:00 AM
  • Firstpage
    109
  • Lastpage
    114
  • Abstract
    Curves are derived and presented which provide a ready means for approximating transfer functions with time constants up to three in number, and also dead time, from the experimental non-oscillatory transient response produced by a step change. The transfer function containing the time constants and dead time may be used to obtain the corresponding frequency response. These curves then are a graphical aid for converting transient response into frequency response.
  • Keywords
    Copper; Corrosion; Frequency response; Steel; Transfer functions; Transient analysis; Transient response;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2185
  • Type

    jour

  • DOI
    10.1109/TAI.1955.6371480
  • Filename