DocumentCode
1372039
Title
Notes on bridged-T complex conjugate compensation and 4-terminal network loading
Author
Chandaket, Prapat ; Rosenstein, Allen B.
Author_Institution
University of California, Los Angeles, Calif.
Volume
78
Issue
3
fYear
1959
fDate
7/1/1959 12:00:00 AM
Firstpage
148
Lastpage
163
Abstract
MANY servo systems possess open-loop transfer functions which contain one or more pairs of complex conjugate poles. Often a pair of these complex conjugate poles will lie close to the imaginary axis and will cause the uncompensated system to possess a relatively poor damping ratio or damping exponent. Usually, satisfactory compensation of such systems can be achieved through the use of tachometer feedback or the conventional compensators possessing real axis singularities. However, there are occasions when complex conjugate singularity compensation would possess distinct advantages. This is particularly true if the compensating complex singularities can be introduced by a simple R-C (resistance-capacitance) passive network with zero d-c attenuation.
Keywords
Damping; Equations; Feedback control; Impedance; Loading; Poles and zeros;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Part II: Applications and Industry, Transactions of the
Publisher
ieee
ISSN
0097-2185
Type
jour
DOI
10.1109/TAI.1959.6371554
Filename
6371554