• DocumentCode
    1374056
  • Title

    A turns index for pulse transformer design

  • Author

    Lord, Harold W.

  • Author_Institution
    General Electric Research Laboratory, Schenectady, N. Y.
  • Volume
    71
  • Issue
    2
  • fYear
    1952
  • fDate
    4/1/1952 12:00:00 AM
  • Firstpage
    165
  • Lastpage
    168
  • Abstract
    FOR a good many years designers of power transformers and distribution transformers have had a guide number to use in starting their first design.1, 2 This is expressed by the equation Vt = K¿kva where Vt is the volts per turn to use in starting the first design; K is a constant which may vary between relatively narrow limits; and kva is the kilovolt-ampere rating of the transformer. In practice, the constant K is about 1.25 for shell-type power transformers, about 0.6 for core-type power transformers, and about 0.4 for core-type distribution transformers.
  • Keywords
    Capacitance; Equations; Indexes; Mathematical model; Power transformers; Pulse transformers; Resistance;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2452
  • Type

    jour

  • DOI
    10.1109/TCE.1952.6371904
  • Filename
    6371904