• DocumentCode
    1374206
  • Title

    Inverter-fed drives: which motor stators are at risk?

  • Author

    Stone, Greg ; Campbell, Steve ; Tetreault, Serge

  • Author_Institution
    Iris Power Eng. of Ontario, Ont., Canada
  • Volume
    6
  • Issue
    5
  • fYear
    2000
  • Firstpage
    17
  • Lastpage
    22
  • Abstract
    This article describes measurements of the surge voltage characteristics from a number of motors driven by inverter-fed drives (IFDs). The measurements were done with both laboratory and purpose-built instrumentation. Further, we discuss why certain surges deteriorate the insulation, and we give guidelines for determining which motors may be at risk of failure from IFD voltage surges. The effect of these surges on stator windings is also included, as well as means to determine if a motor installed in a severe surge environment will fail
  • Keywords
    AC motor drives; invertors; machine insulation; machine testing; stators; surges; voltage measurement; insulation deterioration; inverter-fed drives; motor failure; motor stators; severe surge environment; stator windings; surge voltage characteristics measurement; Instruments; Insulation; Monitoring; Oscilloscopes; Power electronics; Pulse width modulation; Stators; Surges; Transistors; Voltage;
  • fLanguage
    English
  • Journal_Title
    Industry Applications Magazine, IEEE
  • Publisher
    ieee
  • ISSN
    1077-2618
  • Type

    jour

  • DOI
    10.1109/2943.863631
  • Filename
    863631