DocumentCode
1374740
Title
A simplified method for checking the orientation of the optic axis of meter jewels
Author
Knight, S.F.
Volume
97
Issue
56
fYear
1950
fDate
4/1/1950 12:00:00 AM
Firstpage
275
Lastpage
278
Abstract
A simple polarized-light microscope has been developed for checking the orientation of the optic axis of sapphire jewels as used in watt-hour-meter bearings. The method is quick, accurate and simple in use. An accuracy of ±2° is obtained for angles between 80° and 90°.
Keywords
instruments; machine bearings; watthour meters;
fLanguage
English
Journal_Title
Proceedings of the IEE - Part II: Power Engineering
Publisher
iet
Type
jour
DOI
10.1049/pi-2.1950.0082
Filename
5239803
Link To Document