DocumentCode
1375013
Title
The influence of magnetic amplifier circuitry upon the operating hysteresis loops
Author
Lord, Harold W.
Author_Institution
General Electric Company, Schenectady, N. Y.
Volume
72
Issue
6
fYear
1954
Firstpage
721
Lastpage
728
Abstract
THE scope of this paper will be limited to the steady-state characteristics of those high-performance magnetic amplifier circuits which are classed as single-phase self-saturated types. No attempt will be made to indicate when considerations presented herein are applicable to the 100-per-cent external feedback type. Only resistive loads will be considered.
Keywords
Force; Logic gates; Magnetic circuits; Magnetic cores; Magnetic flux; Magnetic hysteresis; Windings;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
Publisher
ieee
ISSN
0097-2452
Type
jour
DOI
10.1109/TCE.1954.6372073
Filename
6372073
Link To Document