DocumentCode
1375449
Title
A digital data-recorder for dense storage of continuous voltages
Author
Hollander, Gerhard L.
Author_Institution
Clevite-Brush Development Company, Cleveland, Ohio
Volume
73
Issue
3
fYear
1954
fDate
7/1/1954 12:00:00 AM
Firstpage
253
Lastpage
259
Abstract
The digital data-recorder stores in digital form continuous voltages from various transducers. It records for 8 minutes with 0.5-per-cent precision one channel of 1,600-cycle bandwidth and eight channels of 200-cycle bandwidth each. The design provides for additional amplitude-modulated (a-m) channels, with a bandwidth up to 80 kc if the operating time is reduced. The volume specification for the recorder is 500 cubic inches. Because of the digital representation of the data, more information can be stored in the limited space, the data can be reduced automatically, and calibration is simplified. While this paper gives block diagrams and wave forms for a specific application, the results are applicable for many instrumentation systems.
Keywords
Bandwidth; Encoding; Films; Generators; Logic gates; Radiation detectors; Switches;
fLanguage
English
Journal_Title
American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
Publisher
ieee
ISSN
0097-2452
Type
jour
DOI
10.1109/TCE.1954.6372148
Filename
6372148