• DocumentCode
    1377307
  • Title

    Operation of a nuclear power plant on an integrated electric system

  • Author

    Wilson, N. E.

  • Author_Institution
    Westinghouse Electric Corporation, Pittsburgh, Pa.
  • Volume
    74
  • Issue
    6
  • fYear
    1956
  • Firstpage
    751
  • Lastpage
    755
  • Abstract
    A nuclear power plant of the pressurized water-moderated and water-cooled type is able to meet the requirements of a central station facility for load changes and for picking up load. It may be used for system load control the same as for conventional plants. The negative temperature coefficient of reactivity characteristic adjusts reactor power level to meet power changes of the steam plant, and provides plant stability. The automatic temperature control system adjusts the control rods to compensate for reactivity changes in the reactor caused by fission products.
  • Keywords
    Fuels; Inductors; Neutrons; Power generation; Water heating; Xenon;
  • fLanguage
    English
  • Journal_Title
    American Institute of Electrical Engineers, Part I: Communication and Electronics, Transactions of the
  • Publisher
    ieee
  • ISSN
    0097-2452
  • Type

    jour

  • DOI
    10.1109/TCE.1956.6372455
  • Filename
    6372455