DocumentCode :
1377336
Title :
Avoiding premature bearing failure with inverter fed induction motors
Author :
Barker, Steve
Volume :
14
Issue :
4
fYear :
2000
Firstpage :
182
Lastpage :
189
Abstract :
The issue of bearing current failures is receiving increasing attention. Traditional bearing current effects with large machines have been well documented, but inverter operation introduces new high-frequency effects. This article therefore highlights potential areas of concern in premature bearing failure, explains the associated mechanisms, and examines the available preventive measures, with the aim of providing essential user guidance.
Keywords :
induction motors; high-frequency effects; inverter operation; inverter-fed induction motors; premature bearing failure; preventive measures;