DocumentCode :
1377423
Title :
Direct Measurement of Power Quality Over Railway Networks With Results of a 16.7-Hz Network
Author :
Mariscotti, Andrea
Author_Institution :
Dept. of Navale & Electr. Eng., Univ. of Genoa, Genoa, Italy
Volume :
60
Issue :
5
fYear :
2011
fDate :
5/1/2011 12:00:00 AM
Firstpage :
1604
Lastpage :
1612
Abstract :
The measurement and monitoring of power quality on electric railway networks is a complex problem with several practical constraints. A digital measurement system was designed and implemented to perform the required task on board different locomotives across several European Union countries. Ease of installation and operation, and robustness are the main requirements. The example of the Swiss alternating-current 16.7-Hz supply network is used to derive information on the pantograph voltage spectrum and its statistical properties and on the visualization and postprocessing methods.
Keywords :
measurement systems; pantographs; power system measurement; railway electrification; European Union; digital measurement system; electric railway network; frequency 16.7 Hz; pantograph voltage spectrum; postprocessing method; power quality over railway network; Harmonic analysis; Noise; Rail transportation; Sensors; Time frequency analysis; Transient analysis; Vehicles; Electric variables measurement; guideway transportation power systems; guideway transportation testing; power distribution electromagnetic interference; power quality (PQ); power system harmonics; power system measurements;
fLanguage :
English
Journal_Title :
Instrumentation and Measurement, IEEE Transactions on
Publisher :
ieee
ISSN :
0018-9456
Type :
jour
DOI :
10.1109/TIM.2010.2089170
Filename :
5634105
Link To Document :
بازگشت