• DocumentCode
    1377423
  • Title

    Direct Measurement of Power Quality Over Railway Networks With Results of a 16.7-Hz Network

  • Author

    Mariscotti, Andrea

  • Author_Institution
    Dept. of Navale & Electr. Eng., Univ. of Genoa, Genoa, Italy
  • Volume
    60
  • Issue
    5
  • fYear
    2011
  • fDate
    5/1/2011 12:00:00 AM
  • Firstpage
    1604
  • Lastpage
    1612
  • Abstract
    The measurement and monitoring of power quality on electric railway networks is a complex problem with several practical constraints. A digital measurement system was designed and implemented to perform the required task on board different locomotives across several European Union countries. Ease of installation and operation, and robustness are the main requirements. The example of the Swiss alternating-current 16.7-Hz supply network is used to derive information on the pantograph voltage spectrum and its statistical properties and on the visualization and postprocessing methods.
  • Keywords
    measurement systems; pantographs; power system measurement; railway electrification; European Union; digital measurement system; electric railway network; frequency 16.7 Hz; pantograph voltage spectrum; postprocessing method; power quality over railway network; Harmonic analysis; Noise; Rail transportation; Sensors; Time frequency analysis; Transient analysis; Vehicles; Electric variables measurement; guideway transportation power systems; guideway transportation testing; power distribution electromagnetic interference; power quality (PQ); power system harmonics; power system measurements;
  • fLanguage
    English
  • Journal_Title
    Instrumentation and Measurement, IEEE Transactions on
  • Publisher
    ieee
  • ISSN
    0018-9456
  • Type

    jour

  • DOI
    10.1109/TIM.2010.2089170
  • Filename
    5634105