• DocumentCode
    1377780
  • Title

    The measurement of blade-tip clearances in aircraft turbines by a capacitance method

  • Author

    Mossop, I.A. ; Gill, F.D.

  • Volume
    100
  • Issue
    76
  • fYear
    1953
  • fDate
    8/1/1953 12:00:00 AM
  • Firstpage
    377
  • Lastpage
    384
  • Abstract
    An instrument has been developed for use by airfield maintenance personnel in the checking of turbine-blade clearances, both in turbo-jet and turbo-prop engines. The measurements are made by plugging a cable into various capacitance pick-up points around the shroud ring and spinning the rotor, cither by hand cranking or by the starter motor. The instrument works on a capacitance principle, but the measurement does not depend for its accuracy on the similarity between the pick-ups; balancing, calibration and¿ultimately¿measurement at a pick-up point are possible without moving the attachment cable, except when changing to the next pick-up. Clearances are indicated on a peak voltmeter, scaled to show the clearance being measured as a fraction of the value to which the instrument has been calibrated. The instrument selects the longest blade and measures its clearance. The instrument has several novel features. The use of a transformer, placed part-way along the pick-up lead and designed to make the whole lead parallel-resonant, not only makes possible the measurement of minute capacitance changes at the end of a long cable but enables a simple resistance bridge to be used for this measurement. This bridge is fed by a stable crystal-controlled 50-kc/s oscillator. With the present equipment it is possible to detect capacitance changes of approximately 0.003 µµF at the end of a cable 23 ft long, requiring an overall capacitance sensitivity, ¿C/C, of 10¿5. The method of calibrating the instrument results in the greatest accuracy of measurement for clearances near the calibration value, the estimated error being less than +5%. The underlying technique may have many other applications in measuring minute capacitance changes, especially where the pick-up is unavoidably remote from the main measuring apparatus.
  • Keywords
    gas turbines; measurement by electrical methods; spatial variables measurement;
  • fLanguage
    English
  • Journal_Title
    Proceedings of the IEE - Part II: Power Engineering
  • Publisher
    iet
  • Type

    jour

  • DOI
    10.1049/pi-2.1953.0124
  • Filename
    5240415