Title :
Closure on “A New Criterion for the Quantification of Broken Rotor Bars in Induction Motors”
Author :
Xu, Boqiang ; Sun, Liling ; Ren, Hui
Author_Institution :
Sch. of Electr. Eng., North China Electr. Power Univ., Baoding, China
Abstract :
We review the corresponding references and find out that there exists a mess indeed. The angular displacement refers to the stator winding impedance angle. It is worth mentioning that the power factor angle approximately equals to the equivalent circuit impedance angle disregarding the rotor asymmetry resulted from an incipient rotor fault. Consequently, it is reasonable to regard the angular displacement as the power factor angle.
Keywords :
angular measurement; induction motors; machine windings; power factor; power factor measurement; angular displacement; broken rotor bars; equivalent circuit impedance angle; induction motors; power factor angle; rotor asymmetry; stator winding impedance angle; Induction motors; Rotors;
Journal_Title :
Energy Conversion, IEEE Transactions on
DOI :