DocumentCode :
1378704
Title :
The measurement of the power factors of insulating oils at 50 c/s
Author :
Martin, R.G. ; Patterson, E.A.
Volume :
100
Issue :
3
fYear :
1953
fDate :
3/1/1953 12:00:00 AM
Firstpage :
68
Lastpage :
72
Abstract :
A modified Schering bridge which, whilst simple in operation, will measure the power factors of insulating oils with a high order of accuracy has been designed and constructed. The power factors of insulating oils are often very low, e.g. 0.00005 or less at room temperature, and considerable care must therefore be taken to avoid small errors which may arise from deficiencies in the electrical circuit, the oil test cell and the measuring technique. An oil test cell available commercially has been modified for use in an oil bath, so that accurate temperature stabilization is rapidly attained, and a method of cleaning and filling the cell has been evolved. Details of cell corrections are given. The procedure described in the paper enables the 50-c/s power factor of an oil to be measured with an error of approximately ±3% ±0.000015.
Keywords :
bridge instruments; dielectric liquids; dielectric loss measurement;
fLanguage :
English
Journal_Title :
Proceedings of the IEE - Part IIA: Insulating Materials
Publisher :
iet
Type :
jour
DOI :
10.1049/pi-2a.1953.0012
Filename :
5240598
Link To Document :
بازگشت